Diagnostic Biochips presents the new Deep Array probe, providing unprecedented single unit recording quality in deep brain structures.

The Deep Array enables chronic and acute recording in NHP and other large animals, with up to 128 microelectrodes integrated on a mechanically robust, yet chronically stable stainless steel substrate.

DA32-1

DA32-1

Max shank length: 90 mm
Shank diameter: 0.2 mm
Site diameter: 20 μm
Recording span: 2.015 mm
Shank material: Stainless steel

32 CHANNEL

Larger View Download Page Download Full Catalog
×

DA32-1

SPECIFICATION DIMENSIONS
Max shank length 90 mm
Shank diameter 0.2 mm
Site diameter 20 μm
Recording span 2.015 mm
Shank material Stainless steel
Download Page

Download Full Catalog
DA32-2

DA32-2

Max shank length: 90 mm
Shank diameter: 0.2 mm
Site diameter: 20 μm
Recording span: 3.1 mm
Shank material: Stainless steel

32 CHANNEL

Larger View Download Page Download Full Catalog
×

DA32-2

SPECIFICATION DIMENSIONS
Max shank length 90 mm
Shank diameter 0.2 μm
Site diameter 20 μm
Recording span 3.1 mm
Shank material Stainless steel
Download Page

Download Full Catalog
DA32-3

DA32-3

Max shank length: 90 mm
Shank diameter: 0.2 mm
Site diameter: 20 μm
Recording span: 6.2 mm
Shank material: Stainless steel

32 CHANNEL

Larger View Download Page Download Full Catalog
×

DA32-3

SPECIFICATION DIMENSIONS
Max shank length 90 mm
Shank diameter 0.2 μm
Site diameter 20 μm
Recording span 6.2 mm
Shank material Stainless steel
Download Page

Download Full Catalog
DA64-1

DA64-1

Max shank length: 90 mm
Shank diameter: 0.2 mm
Site diameter: 20 μm
Recording span: 6.3 mm
Shank material: Stainless steel

64 CHANNEL

Larger View Download Page Download Full Catalog
×

DA64-1

SPECIFICATION DIMENSIONS
Max shank length 90 mm
Shank diameter 0.2 μm
Site diameter 20 μm
Recording span 6.3 mm
Shank material Stainless steel
Download Page

Download Full Catalog
DA64-2

DA64-2

Max shank length: 90 mm
Shank diameter: 0.2 mm
Site diameter: 20 μm
Recording span: 1.575 mm
Shank material: Stainless steel

64 CHANNEL

Larger View Download Page Download Full Catalog
×

DA64-2

SPECIFICATION DIMENSIONS
Max shank length 90 mm
Shank diameter 0.2 μm
Site diameter 20 μm
Recording span 1.575 mm
Shank material Stainless steel
Download Page

Download Full Catalog
DA128-1

DA128-1

Max shank length: 90 mm
Shank diameter: 0.2 mm
Site diameter: 20 μm
Recording span: 5.08 mm
Shank material: Stainless steel

128 CHANNEL

Larger View Download Page Download Full Catalog
×

DA128-1

SPECIFICATION DIMENSIONS
Max shank length 90 mm
Shank diameter 0.2 μm
Site diameter 20 μm
Recording span 5.08 mm
Shank material Stainless steel
Download Page

Download Full Catalog
DA128-2

DA128-2

Max shank length: 90 mm
Shank diameter: 0.2 mm
Site diameter: 20 μm
Recording span: 3.175 mm
Shank material: Stainless steel

128 CHANNEL

Larger View Download Page Download Full Catalog
×

DA128-2

SPECIFICATION DIMENSIONS
Max shank length 90 mm
Shank diameter 0.2 μm
Site diameter 20 μm
Recording span 3.175 mm
Shank material Stainless steel
Download Page

Download Full Catalog

 

Additional Products You May Be Interested In

Powerful, elegant, easy-to-use systems for electrophysiology

Rect_probelistingforchart (1)

Silicon Acute & Chronic

The days of large, expensive recording electronics are gone. DBC’s probe interface box (based on the open-ephys system) is all you need to begin streaming data.

Find Out More >

Rect_neurogrid-1 (1)

Micro EcOG

The days of large, expensive recording electronics are gone. DBC’s probe interface box (based on the open-ephys system) is all you need to begin streaming data.

Find Out More >

Rect_JanusProbe (1)

Janus Probe

For both acute and chronic (drivable, floating and fixed preparations) we provide all that you need to successfully implant and use laminar and surface electrodes.

Find Out More >

Rect_cloudbasedscreen-1-1

Cloud-based Software

For both acute and chronic (drivable, floating and fixed preparations) we provide all that you need to successfully implant and use laminar and surface electrodes.

Find Out More >

Get in Touch

We’d love to talk to you about your needs and how we can help.